PL750/2S
|
| Tank Diameter with/without Insulation (D/Dsp) |
40/32" (1000/800 mm) |
| Tank Height (H) |
75.6* (1920 mm) |
| Net Weight (Dry) |
556 lbs (252 kg) |
| Total Capacity |
200 gal (750 l) |
| Boiler Water Capacity |
73 gal (275 l) |
| DHW Total Capacity/DHW Standby Portion |
80/40 gal (300/1500 l) |
| Solar Indirect Coil Capacity |
0.37 gal (1.4 l) |
| Solar Indirect Coil Length |
11 ft² (1.0 m²) |
| Standby Heat Loss |
13,000 BTU/day (3.7kWh/24h) |
| Continuous Output (Upper Indirect Coil) with 176/113/50°F (80/45/10°C) |
96,000 BTU/Hr [182 gph]
(28kW[688 l/hr]) |
| Max. Operating Pressure (Solar Indirect Coil/Boiler Water/DHW) |
116/44/145 psi (8/3/10 bar) |
| Max. Operating Temperature Heating Water/DHW |
203°F (95°C) |
| |
| |
Pipe Size |
Height
from Ground |
| Cold Water Inlet (EK) |
1" |
.31" (8 mm) |
| Cold Water Drain (EL) |
1¼" |
8.5 (215 mm) |
| Solar/DHW Drain (EL1/E2) |
¾" |
3.9" (100 mm) |
| Storage Tank Return on the Solar Side (RS1) |
¾" |
|
| Storage Tank Supply on the Solar Side (VS1) |
¾" |
6.7" (170 mm) |
| Return, Oil/Gas Fired/Condensing Boiler for DHW Heating (RS2) |
1¼" |
40.7" (1033 mm) |
| Supply, Oil/Gas Fired/Condensing Boiler for DHW Heating (VS2) |
1¼" |
65.7" (1668 mm) |
| Return, Oil/Gas Fired Boiler (RS2) |
1¼" |
19.7" (550 mm) |
| Supply, Oil/Gas Fired Boiler (VS5) |
1¼" |
31" (788 mm) |
| Return, Boiler Circuits (RS4) |
1¼" |
14.6" (370 mm) |
| Supply, Boiler Circuits (VS4) |
1¼" |
35.9" (911 mm) |
| Return, Solid Fuel Boiler (RS5) |
1¼" |
|
| Supply, Solid Fuel Boiler (VS2) |
1¼" |
65.7" (1668 mm) |
| DHW Circulation Inlet (EZ) |
¾" |
|
| DHW Outlet (AW) |
1¾" |
|
| |
|
|
* Boiler water supply temperature/DHW outlet temperature/cold domestic water inlet temperature.